POND AERATOR
The dissolved oxygen concentration within Cardiff Bay are maintained at or above 5mg/l. Compressed air is pumped, from five sites around the Bay, through a series of steel reinforced rubber pipelines, laid on the beds of the Bay and Rivers Taff and Ely. These are connected to approximately 800 diffusers. At times this is insufficient and the Harbour Authority is using a mobile oxygenation barge built by McTay Marine with liquid oxygen stored in a tank. Liquid oxygen is passed through an electrically heated vapouriser and the gas is injected into a stream of water which is pumped from, and returned to, the bay. The barge is capable of dissolving up to 5 tonnes of oxygen in 24 hours.